World Journal of Pharmaceutical
and Medical Research

( An ISO 9001:2015 Certified International Journal )

An International Peer Reviewed Journal for Pharmaceutical and Medical Research and Technology
An Official Publication of Society for Advance Healthcare Research (Reg. No. : 01/01/01/31674/16)
ISSN 2455-3301
IMPACT FACTOR: 6.842

ICV : 78.6

World Journal of Pharmaceutical and Medical Research (WJPMR) has indexed with various reputed international bodies like : Google Scholar , Index Copernicus , SOCOLAR, China , Indian Science Publications , Cosmos Impact Factor , Research Bible, Fuchu, Tokyo. JAPAN , Scientific Indexing Services (SIS) , UDLedge Science Citation Index , International Impact Factor Services , International Society for Research Activity (ISRA) Journal Impact Factor (JIF) , International Innovative Journal Impact Factor (IIJIF) , Scientific Journal Impact Factor (SJIF) , Global Impact Factor (In Process) , Digital Online Identifier-Database System (DOI-DS) , Science Library Index, Dubai, United Arab Emirates , Eurasian Scientific Journal Index (ESJI) , International Scientific Indexing, (ISI) UAE , IFSIJ Measure of Journal Quality , Web of Science Group (Under Process) , Directory of Research Journals Indexing , Scholar Article Journal Index (SAJI) , International Scientific Indexing ( ISI ) , Scope Database , Academia , 

Abstract

UPLC METHOD DEVELOPMENT AND VALIDATION FOR SIMULTANEOUS ESTIMATION OF SOFOSBUVIR AND LEDIPASVIR IN TABLET DOSAGE FORM

M. Prashanthi Evangelin*, S. Manohar Babu, Konda Ravi Kumar and P. Sunitha

ABSTRACT

A simple, precise, specific and stability-indicating UPLC (Ultra Performance Liquid Chromatography) method was developed and validated for the simultaneous estimation of anti-viral drugs Simeprevir and Sofosbuvir in combined dosage form. The method was developed using SD C18 column (100 mm×2.1 mm, 1.8?m) with isocratic elution. 0.1% ortho phosphoric acid buffer and acetonitrile (60:40 v/v) were used as mobile phase with 0.2 ml/min flow rate at ambient temperature. The detection wavelength was fixed at 220 nm. The run time was within 2 min. The method was validated in terms of linearity, accuracy and reproducibility. Calibration plots were linear over the range of 37.5-225 ?g/ml for Simeprevir and 100-600 ?g/ml for Sofosbuvir. The Recovery was in the range of 98-102% with the relative standard deviation of less than 2% for both drugs. The mean recoveries were found to be 99.41% and 99.91% for Simeprevir and Sofosbuvir respectively. The relative standard deviation (RSD) was found to be < 2.0% for both drugs. The limit of detection and the limit of quantification for the Simeprevir were found to be 0.51 and 1.55 ?g/ml respectively and for Sofosbuvir 0.50 and 1.52 ?g/ml respectively. The proposed method was validated and successfully applied to the estimation of Simeprevir and Sofosbuvir in tablet dosage form.

[Full Text Article]    [Download Certificate]

Powered By WJPMR | All Right Reserved

WJPMR