World Journal of Pharmaceutical
and Medical Research

( An ISO 9001:2015 Certified International Journal )

An International Peer Reviewed Journal for Pharmaceutical and Medical Research and Technology
An Official Publication of Society for Advance Healthcare Research (Reg. No. : 01/01/01/31674/16)
ISSN 2455-3301
IMPACT FACTOR: 6.842

ICV : 78.6

World Journal of Pharmaceutical and Medical Research (WJPMR) has indexed with various reputed international bodies like : Google Scholar , Index Copernicus , SOCOLAR, China , Indian Science Publications , Cosmos Impact Factor , Research Bible, Fuchu, Tokyo. JAPAN , Scientific Indexing Services (SIS) , UDLedge Science Citation Index , International Impact Factor Services , International Society for Research Activity (ISRA) Journal Impact Factor (JIF) , International Innovative Journal Impact Factor (IIJIF) , Scientific Journal Impact Factor (SJIF) , Global Impact Factor (In Process) , Digital Online Identifier-Database System (DOI-DS) , Science Library Index, Dubai, United Arab Emirates , Eurasian Scientific Journal Index (ESJI) , International Scientific Indexing, (ISI) UAE , IFSIJ Measure of Journal Quality , Web of Science Group (Under Process) , Directory of Research Journals Indexing , Scholar Article Journal Index (SAJI) , International Scientific Indexing ( ISI ) , Scope Database , Academia , 

Abstract

METHOD DEVELOPMENT AND VALIDATION FOR SIMULTANEOUS ESTIMATION OF L-METHYL FOLATE & ESCITALOPRAM BY RP-HPLC METHOD

Vardhanapu Mary Bharathi*, Dr. Devanaboyina Narendra, Gadi Vijaya Lakshmi, Yendamuri Narayudu, Penumantra Venkata Kishore

ABSTRACT

A simple, Accurate, precise method was developed for the simultaneous estimation of the L-methyl folate and Escitalopram in Tablet dosage form. Chromatogram was run through Waters C18 150 x 4.6 mm, 5?. Mobile phase containing Buffer 0.01N KH2PO4 (3.45pH): Acetonitrile taken in the ratio 50:50 was pumped through column at a flow rate of 1.0 ml/min. Buffer used in this method was 0.01N KH2PO4. Temperature was maintained at 30°C. Optimized wavelength selected was 212 nm. Retention time of L-methyl folate and Escitalopram were found to be 2.263min and 3.079min. %RSD of the L-methyl folate and Escitalopram were and found to be 0.2 and 0.5 respectively. %Recovery was obtained as 99.79% and 100.54% for L-methyl folate and Escitalopram respectively. LOD, LOQ values obtained from regression equations of L-methyl folate and Escitalopram were 0.24, 0.29 and 0.72, 0.87 respectively. Regression equation of L-methyl folate is y = 22979x + 8347. and y = 31569x + 3873. of Escitalopram. Retention times were decreased and run time was decreased, so the method developed was simple and economical that can be adopted in regular Quality control test in Industries.

[Full Text Article]    [Download Certificate]

Powered By WJPMR | All Right Reserved

WJPMR